| D1040Q | 4 Separated Channels; 1 + 1 + 1 + 1 72 mA Imax; 334 Ω; SIL 3 (LP) / SIL 2 (BS) | 4 | , A, R, UL, FM,E,M | 22 | ||||||||||||
| 2 + 2 Channels in parallel; 2 + 2 144 mA Imax; 167 Ω; SIL 3 (LP) / SIL 2 (BS) | 2 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| 3 Channels in parallel; 1 216 mA Imax; 111 Ω; SIL 3 (LP) / SIL 2 (BS) | 1 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| 4 Channels in parallel; 1 288 mA Imax; 84 Ω; SIL 3 (LP) / SIL 2 (BS) | 1 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| D1041Q | 4 Channels to drive LEDs; 1 + 1 + 1 + 1 49,6 mA Imax; 484 Ω; SIL 3 (LP) / SIL 2 (BS) | 4 | , A, R, UL, FM,E,M | 22 | ||||||||||||
| D1042Q | 4 Separated Channels, 1 + 1 + 1 + 1 88,2 mA Imax; 273 Ω; SIL 3 (LP) / SIL 2 (BS) | 4 | , A, R, UL, FM,E,M | 22 | ||||||||||||
| 2 + 2 Channels in parallel, 2 + 2 176,4 mA Imax; 137 Ω; SIL 3 (LP) / SIL 2 (BS) | 2 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| 3 Channels in parallel, 1 264,6 mA Imax; 91 Ω; SIL 3 (LP) / SIL 2 (BS) | 1 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| 4 Channels in parallel, 1 352,8 mA Imax; 68 Ω; SIL 3 (LP) / SIL 2 (BS) | 1 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| D1043Q | 4 Separated Channels, 1 + 1 + 1 + 1 49,6 mA Imax; 484 Ω; SIL 3 (LP) / SIL 2 (BS) | 4 | , A, R, UL, FM,E,M | 22 | ||||||||||||
| 2 + 2 Channels in parallel, 2 + 2 99,2 mA Imax; 242 Ω; SIL 3 (LP) / SIL 2 (BS) | 2 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| 3 Channels in parallel, 1 148,8 mA Imax; 161 Ω; SIL 3 (LP) / SIL 2 (BS) | 1 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| 4 Channels in parallel, 1 198,4 mA Imax; 121 Ω; SIL 3 (LP) / SIL 2 (BS) | 1 | , A, R, UL, FM,E,M | 22 | |||||||||||||
| D1045Y | 2 Channels for ATOS Valve 177/199 mA Imax; 163 / 21 Ω | 2 | I, A, FM | 22 | ||||||||||||
| D1046Y | 2 Channels for WANDFLUH Valve 350 Imax; 121 Ω | 2 | I, A, FM | 22 | ||||||||||||
| D1047S | 1 Ch; ND Loads; Loop Powered; Line&Valve Monitoring Function; Selectable Ooutput; SIL 3 (1 yr) | 1 | I, A, FM | 22 | ||||||||||||
| D1048S | 1 Ch; NE Loads; Loop/Bus Powered; Line & Valve Monitoring Function; Selectable Output; SIL 3 | 1 | I, A, FM | 22 | ||||||||||||
| D1049S | 1 Ch; ND Loads; Loop/Bus Powered; Line & Valve Monitoring Function; Selectable Output; SIL 3 | 1 | I, A, FM | 22 | ||||||||||||
| D5000 Series | ||||||||||||||||
| D5247S | 1 Ch; Redund. (1oo2) Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Fnct; SIL 3 | 1 | - | 22 | ||||||||||||
| Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection | ||||||||||||||||
| D5048S | 1 Ch; Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL 3 (20 yr) | 1 | I, A, T | 12 | ||||||||||||
| Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection | ||||||||||||||||
| D5049S | 1 Ch; Solenoid Driver; Bus Powered; Transparent Line & Load Alarm Function; SIL 3 (1 Yr) | 1 | I, A, T | 12 | ||||||||||||
| Unit has three field selectable Valve power Outputs; Both Open and Short Circuit Fault Detection | ||||||||||||||||
| DIGITAL OUTPUT / RELAY OUTPUT I.S. MODULES | ||||||||||||||||
| D1000 Series | ||||||||||||||||
| D1044S | 1 Channel; 1 SPDT Relay Output to Hazardous Location | 1 | I, A, FM | 22 | ||||||||||||
| D1044D | 2 Channel; 2 SPDT Relay Outputs to Hazardous Location | 2 | I, A, FM | 22 | ||||||||||||
| DIGITAL OUTPUT / HIGH POWER NON I.S. MODULES | ||||||||||||||||
| D1000 Series | ||||||||||||||||
| D1098S | 1 Ch; 24 Vdc 12 W Digital Output Isolated Module; Output for NE Load; SIL 3 (3Yr) | 1 | Not Applicable | 22 | ||||||||||||
| With Line and Load Short and Breakage Diagnostic Detection | ||||||||||||||||
| D1099S | 1 Ch; 24 Vdc 12 W Digital Output Isolated Module; Output for ND Load; SIL 3 (3Yr) | 1 | Not Applicable | 22 | ||||||||||||
| With Line and Load Short and Breakage Diagnostic Detection | ||||||||||||||||
| D5000 Series | ||||||||||||||||
| D5280S | 1 Ch; Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL 3 | 1 | Not Applicable | 22 | ||||||||||||
| 24V, 500 mA - 12 Watts Power Output; Both Open and Short Circuit Fault Detection | ||||||||||||||||
| D5281S | 1 Ch; (1oo2) Solenoid Driver; Loop Powered; Transparent Line & Load Alarm Function; SIL 3 | 1 | Not Applicable | 22 | ||||||||||||
| 24V, 500 mA - 12 Watts Power Output; Both Open and Short Circuit Fault Detection | ||||||||||||||||
| Certifications | I= IEC; A= ATEX; R= GOST; UL= Underwriter Laboratories; FM= Factory Mutual; T= TUV; E= Exida; M= Marine; Up to date info: www.gmintsrl.com | |||||||||||||||
| Notes | D = Din Rail Mounting; DB = Power Bus Mounting; BR = Board Mounting; LP = Loop Power; NA = Not Available; SIL2, SIL3 according IEC61508 and IEC61511; (yr) = Tproof Test Interval Time in Years. Size = Width in mm | |||||||||||||||
| Page # 5 | ||||||||||||||||
| Export Price List 2011 ( Rev. 0 dated December 23rd 2010 ) | ||||||||||||||||
| Code | Description | Ch | Certifications | Size | ||||||||||||
| D1000 Series | ||||||||||||||||
| D1052S | 1 Ch; mA, V - Input, Output; Fully Software Programmable; SIL 2 (5 yr) | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1052D | 2 Ch; mA, V - Input, Output; Fully Software Programmable; SIL 2 (5 yr) | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1052X | 1 Input-2 Outputs Ch; Duplicator; mA-V, mA, V - Input, Output; Fully Software Programmable | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1052Y | 2 Ch; mA, V - Input, Output; High-Low Selector / Summer / Adder; Fully Software Programmable | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1053S | 1 Ch; mA, V - Input, Output + 2 Trip Amplifiers; Fully Software Programmable; SIL 2 (1 yr) | 1 | I,A,R,UL,FM,E,M | 22 | ||||||||||||
| D1053S-021 | 1 Ch; mA, V - Input, Output + 2 Trip Amplifiers; Fully Software Program; SIL 2 (1 yr); 10 Vdc PS | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1054S | 1 Ch; Smart-Hart; 0/4-20 mA Input; mA-V Output + 2 Trip Amp; Fully Softw. Program; SIL 2 (5 yr) | 1 | I, A, R, FM, M | 22 | ||||||||||||
| TEMPERATURE INPUT I.S. MODULES | ||||||||||||||||
| D1000 Series | ||||||||||||||||
| D1072S | 1 Ch; TC-RTD-Tx Pot Input; mA-V Output; Fully Software Programmable; SIL 2 (1 yr) | 1 | I,A,R,UL,FM,E,M | 22 | ||||||||||||
| D1072D | 2 Ch; TC-RTD-Tx Pot Input; mA-V Outputs; Fully Soft. Program; ( X & Y Function); SIL 2 (1 yr) | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1072S-024 | 1 Ch; 0-80 or 16-80 mV Input / Output; Fully Software Programmable | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1072D-024 | 2 Ch; 0-80 or 16-80 mV Input / Output; Fully Software Programmable | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1072D-028 | 2 Ch; Input & Output According to APN0008 | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1073S | 1 Ch; TC-RTD-Tx Pot IN; mA / V OUT + 2 Trip Amplifiers; Fully Software Program; SIL 2 (1 yr) | 1 | I,A,R,UL,FM,E,M | 22 | ||||||||||||
| D1073S-032 | 1 Ch. TC-RTD-Tx Pot IN; mA / V OUT + 2 Trip Amp; Fully Software Program; SIL 2 (1 yr); 10 Vdc | 1 | I,A,R,UL,FM,E,M | 22 | ||||||||||||
| D5000 Series | ||||||||||||||||
| D5072S | 1 Ch; TC-RTD-Tx Pot Input; mA-V plus Burnout Alarm Outputs; Fully Programmable, SIL 2 (5 yr) | 1 | - | 12 | ||||||||||||
| D5072D | 2 Ch; TC-RTD-Tx Pot Input; mA-V Outputs; Fully Programmable, SIL 2 (5 yr) | 2 | - | 12 | ||||||||||||
| Unit is field configurable as Duplicator 1 IN - 2 OUT | ||||||||||||||||
| D5074S | 2/1 Ch; N° 2 TC-RTD-Tx Pot Inputs; N° 1 mA-V Output; Fully Programmable, SIL 3 (1 yr) | 1 | - | 12 | ||||||||||||
| TEMPERATURE INPUT NON I.S. MODULES | ||||||||||||||||
| D1000 Series | ||||||||||||||||
| D1072D-059 | 2 Ch; TC-RTD-Tx Pot Input; mA-V Outputs; Fully Software Programmable; ( X & Y Function) | 2 | Not Applicable | 22 | ||||||||||||
| FREQUENCY / ENCODER INPUT I.S. MODULES | ||||||||||||||||
| D1000 Series | ||||||||||||||||
| D1035S | 1 Ch; Contact-Prox-LL-Magnetic Pick-up Input; 0 -50 KHz Range; Pulse Output | 1 | I, A, FM, M | 22 | ||||||||||||
| D1060S | 1 Ch; Cont-Prox-LL-Magnetic Pick-up Input; 0 -50 KHz Range; Pulse + mA-V + Trip Ampl. Output; | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| Fully Software Programmable | ||||||||||||||||
| D1060S-049 | 1 Ch; Cont-Prox-LL-Magnetic Pick-up Input; 0 -50 KHz Range; Pulse + mA-V + Trip Ampl. Output; | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| Special Version with Clamping Diode; Fully Software Programmable | ||||||||||||||||
| D5000 Series | ||||||||||||||||
| D5060S | 1 Ch; 0 -50 KHz Frequency Input; Analog Output plus Pulse Repeat or Alarm Output | 1 | - | 12 | ||||||||||||
| D5265S | 1 Ch, I.S. Encoder Input; A, B, Z Outputs | 1 | - | 22 | ||||||||||||