| D1010S | 1 Ch; Smart-Hart; Active-Passive Input; Sink-Source Output; SIL 3 (1yr) / SIL 2 (5yr) | 1 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1010D | 2 Ch; Smart-Hart; Active-Passive Inputs; Sink-Source Out; Duplicator; SIL 3 (1yr) / SIL 2 (5yr) | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1010S-026 | 1 Ch; 4-20 mA Input; 0-20 mA / 0-10 V Output | 1 | I, A | 22 | ||||||||||||
| D1010D-026 | 2 Ch; 4-20 Input; 0-20 mA / 0-10 V Outputs | 2 | I, A | 22 | ||||||||||||
| D1010S-041 | 1 Ch; 0-1.4 mA Input; 0-20 mA / 0-5 V Output | 1 | I, A | 22 | ||||||||||||
| D1010D-041 | 2 Ch; 0-1.4 mA Inputs; 0-20 mA / 0-5 V Outputs | 2 | I, A, | 22 | ||||||||||||
| D1010S-043 | 1 Ch; 0-450 mV Input; 0-1.4 mA Output | 1 | I, A, | 22 | ||||||||||||
| D1010D-043 | 2 Ch; 0-450 mV Inputs; 0-1.4 mA Outputs | 2 | I, A, R | 22 | ||||||||||||
| D1010S-046 | 1 Ch; Smart-Hart; Active-Passive IN; Sink-Source OUT; Low Parameter; SIL 3 (1yr) / SIL 2 (5yr) | 1 | I, A, R, E | 22 | ||||||||||||
| D1010D-046 | 2 Ch; Smart-Hart; Act.-Pass. IN; Sink-Source OUT; Duplicator; Low Par; SIL 3 (1yr) / SIL 2 (5yr) | 2 | I, A, R, E | 22 | ||||||||||||
| D1010S-047 | 1 Ch; 4-20 mA Input; 0-5 V or 0-10 V Output | 1 | I, A, R | 22 | ||||||||||||
| D1010D-047 | 2 Ch; 4-20 mA Input; 0-5 V or 0- 10 V Output | 2 | I, A, R | 22 | ||||||||||||
| D1010S-048 | 1 Ch; 0/4-20 mA Input; 0/0,2-1 mA Output | 1 | I, A, R | 22 | ||||||||||||
| D1010D-048 | 2 Ch; 0/4-20 mA Inputs; 0/0,2-1 mA Outputs | 2 | I, A, R | 22 | ||||||||||||
| D1010S-054 | 1 Ch; -5 - +55 mV Inputs; 4-20 mA Output, SIL 2 (5yr) | 1 | A, R, FM, E, T | 22 | ||||||||||||
| D1010S-056 | 1 Ch; -5 - +35 mV Inputs; 4-20 mA Output, SIL 2 (5yr) | 1 | A, R, FM, E, T | 22 | ||||||||||||
| D1010S-057 | 1 Ch; -5 - +10 mV Inputs; 4-20 mA Output, SIL 2 (5yr) | 1 | A, R, FM, E, T | 22 | ||||||||||||
| D1012Q | 4 Ch; 4-20 mA Passive non Isolated Inputs; 4-20 mA Source Output | 4 | I, A, R, FM, M | 22 | ||||||||||||
| D1014S | 1 Ch; Hart; 4-20 mA Passive Input; 4-20 mA Sink-Source Output; SIL 3 (1yr)/SIL 2 (10yr) | 1 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1014S-060 | 1 Ch; Hart; 4-20 mA Passive IN; 4-20 mA Sink-Source OUT; 1 KΩ Load; SIL 3 (1yr)/SIL 2 (10yr) | 1 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1014D | 2 Independent Ch; Hart; 4-20 mA Pass. IN; 4-20 mA Sink-Source Output; SIL 3 (1yr)/SIL 2 (10yr) | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D5000 Series | ||||||||||||||||
| D5011S | 1 Ch; 4-20 mA 2-Wire IN; 4-20mA Source OUT; Hart; SIL 3 (1 yr) / SIL 2 (10yr) | 1 | I, A, T | 12 | ||||||||||||
| D5011D | 2 Independent Ch; 4-20 mA 2-Wire IN; 4-20mA Source OUT; Hart; SIL 3 (1yr) / SIL 2 (10yr) | 2 | I, A, T | 12 | ||||||||||||
| D5014S | 1 Ch; 0/4-20 mA, 2/3-Wire IN; mA/V Sink/Source OUT; Hart; SIL 3 (1 yr) / SIL 2 (10yr) | 1 | I, A, T | 12 | ||||||||||||
| D5014D | 2 Independent Ch; 0/4-20 mA, 2/3-Wire IN; mA/V Sink/Source OUT; Hart; SIL 3 (1 yr) / SIL 2 (10yr) | 2 | I, A, T | 12 | ||||||||||||
| Unit is field configurable as Duplicator 1 IN - 2 OUTs | ||||||||||||||||
| 4 Ch; 4-20 mA IN/OUT; Configurable as Duplicator, Triplicator or Quadruplicator | 4 | - | 22 | |||||||||||||
| ANALOGUE OUTPUT I.S. MODULES | ||||||||||||||||
| D1000 Series | ||||||||||||||||
| D1020S | 1 Ch; Smart-Hart; Isolating Driver for I/P; 0/4-20 mA IN-OUT; SIL 2 (1yr) | 1 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1020D | 2 Independent Ch; Smart-Hart; Isolating Driver for I/P; o/4-20 mA IN-OUT; SIL 2 (1yr) | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1020S-027 | 1 Ch; Smart-Hart; Isolating Driver for I/P; Input 2 - 10 V; Output 4-20 mA | 1 | A, R | 22 | ||||||||||||
| D1020D-027 | 2 Ch; Smart-Hart; Isolating Driver for I/P; Input 2 - 10 V; Output 4-20 mA | 2 | A, R | 22 | ||||||||||||
| D1020S-050 | 1 Ch; Smart-Hart; Isolating Driver for I/P; Input 0 - 10 V; Output 4-20 mA | 1 | A, R, FM | 22 | ||||||||||||
| D1020D-050 | 2 Ch; Smart-Hart; Isolating Driver for I/P; Input 0 - 10 V; Output 4-20 mA | 1 | A, R, FM | 22 | ||||||||||||
| D1020S-067 | 1 Ch; Smart-Hart; Isolating Driver for I/P; Input 1 - 5 V; Output 4-20 mA | 1 | A, R, | 22 | ||||||||||||
| D1020D-067 | 2 Ch; Smart-Hart; Isolating Driver for I/P; Input 1 - 5 V; Output 4-20 mA | 2 | A, R | 22 | ||||||||||||
| D1020S-074 | 1 Ch; Smart-Hart; Isolating Driver for I/P; Input 0 - 4 V; Output 4-20 mA | 1 | A, R | 22 | ||||||||||||
| D1021S | 1 Ch; Smart-Hart; Isolating Driver for I/P; Line Monitoring Function with alarm OUT; SIL 2 (1yr) | 1 | I, A, R, FM, E, M | 22 | ||||||||||||
| D1022S | 1 Ch; Gas-Fire Detector Interface; Loop Powered 0-40 mA IN/OUT | 1 | I, A, FM, M | 22 | ||||||||||||
| D1022D | 2 Ch; Gas-Fire Detector Interface; Loop Powered 0-40 mA IN/OUT | 2 | I, A, FM, M | 22 | ||||||||||||
| D5000 Series | ||||||||||||||||
| D5020S | 1 Ch; 4-20 mA, I/P Driver; Transparent Open-Short Circuit Alarm Function; Hart SIL 2 (3 yr) | 1 | I, A, T | 12 | ||||||||||||
| D5020D | 2 Independent Ch; 4-20 mA, I/P Driver; Transparent Open-Short Circuit Alarm Function; SIL2 (3 yr) | 2 | I, A, T | 12 | ||||||||||||
| Unit is field configurable as Duplicator 1 IN - 2 OUTs | ||||||||||||||||
| Certifications | I= IEC; A= ATEX; R= GOST; UL= Underwriter Laboratories; FM= Factory Mutual; T= TUV; E= Exida; M= Marine; Up to date info: www.gmintsrl.com | |||||||||||||||
| Notes | SV = Special Version non stock delivery; D = Din Rail Mounting; DB = Power Bus Mounting; BR = Board Mounting; SIL2, SIL3 according IEC61508 and IEC61511; (yr) = Tproof Test Interval Time in Years. Size = Width in mm | |||||||||||||||
| Page # 3 | ||||||||||||||||
| Export Price List 2011 ( Rev. 0 dated December 23rd 2010 ) | ||||||||||||||||
| Code | Description | Ch | Certifications | Size | ||||||||||||
| DIGITALI INPUT I.S. MODULES | ||||||||||||||||
| D1000 Series | ||||||||||||||||
| D1030S | 1 Ch; 1 + 1 Relay Output SPDT (Duplication or LD Alarm); Line Monitoring Function | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1030D | 2 Ch; 2 Relay Outputs SPDT; Line Monitoring Function | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1130S | 1 Ch; 1 + 1 Relay Output SPDT (Duplication or LD Alarm); Line Monitoring Function; AC Power | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1130D | 2 Ch; 2 Relay Outputs SPDT ; Line Monitoring Function; AC Power | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1030S-018 | 1 Ch; 1 + 1 Relay Output SPDT (Duplication or LD Alarm); Line Monitoring Function; 10VDC PS | 1 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1030D-018 | 2 Ch; 2 Relay Outputs SPDT; Line Monitoring Function; 10 VDC Power Supply | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1031D | 2 Ch; 2+2 OC Transistor Outputs (Duplication or LD Alarm); Line Monitoring Function; 1 KHz Max | 2 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1031Q | 4 Ch; 4 OC Transistor Outputs; Line Monitoring Function; 1 KHz Max | 4 | I, A, R, UL, FM, M | 22 | ||||||||||||
| D1032D | 2 Isolated Ch; 2+2 Relay Outputs SPST (Duplication or LD Alarm); Line Mon. Func.; SIL 2 (5yr) | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1032Q | 4 Isolated Ch; 4 Relay Outputs SPST, Line Monitoring Function; SIL 2 (5yr) | 4 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1033D | 2 Isolated Ch; 2+2 OC Transistor Outputs (Duplication or LD Alarm); Line Mon. Func; SIL 2 (5yr) | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1033Q | 4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function; SIL 2 (5yr) | 4 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1033D-052 | 2 Iso. Ch; 2+2 OC Trans. Out (Dupl. or LD Alarm); Line Mon. Func; SIL 2 (5yr) Common Negative | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1033Q-052 | 4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function, SIL 2 (5yr) Common Negative | 4 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1033D-058 | 2 Iso. Ch; 2+2 OC Trans. Out (Dupl. or LD Alarm); Line Mon. Func; SIL 2 (5yr) Common Positive | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1033Q-058 | 4 Isolated Ch; 4 OC Transistor Outputs; Line Monitoring Function, SIL 2 (5yr) Common Positive | 4 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1034S | 1 Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 3 (1 yr) / SIL 2 (10 yr) | 1 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D1034D | 2 Isolat. Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 3 (1yr) / SIL 2 (10yr) | 2 | I,A,R,UL,FM,T,E,M | 22 | ||||||||||||
| D5000 Series | ||||||||||||||||
| D5030S | 1 Ch; 1 SPDT Relay Output; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr) | 1 | I, A, T | 12 | ||||||||||||
| D5030D | 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr) | 2 | I, A, T | 12 | ||||||||||||
| Unit is field configurable as Duplicator: 1 IN / 2 OUTs or 1 IN - 1+1 OUT (DI + LMF) | ||||||||||||||||
| D5031S | 1 Ch; 1 NO/NC Solid State Output; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr) | 1 | I, A, T | 12 | ||||||||||||
| D5031D | 2 Independent Ch; 2 NO/NC Transistor Out; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr) | 2 | I, A, T | 12 | ||||||||||||
| Unit is field configurable as Duplicator: 1 IN / 2 OUTs or 1 IN - 1+1 OUT (DI + LMF) | ||||||||||||||||
| D5231E | 8 Ch; NO/NC Solid State Output; Line Monitoring Function; SIL 2 | 8 | - | 22 | ||||||||||||
| D5032S | 1 Ch; 1 SPDT Relay Output; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr) | 1 | I, A, T | 12 | ||||||||||||
| D5032D | 2 Independent Ch; 2 SPST Relay Outputs; Line Monitoring Function; SIL 3 (2 yr) / SIL 2 (20yr) | 2 | I, A, T | 12 | ||||||||||||
| Unit is field configurable as Duplicator: 1 IN / 2 OUTs or 1 IN - 1+1 OUT (DI + LMF) | ||||||||||||||||
| D5034S | 1 Ch; Trasparent to Contact-Proximity & Line Monitoring Function; SIL 3 (1 yr) / SIL 2 (10 yr) | 1 | I, A, T | 12 | ||||||||||||
| D5034D | 2 Independend Ch; Trasparent to Contact-Prox & Line Monitoring Function; SIL 3 (1 yr) / SIL 2 (10 yr) | 2 | I, A, T | 12 | ||||||||||||