| TB-D5008-GMI-001 | N° 8 / 12mm Modules AI-AO-DI-DO Board with ELCO 56 Pin Output + Hart Connectors | 16 | Not Applicable | |||||||||||||
| TB-D5016-GMI-001 | N° 16 / 12mm Modules AI-AO-DI-DO Board with ELCO 56 Pin Output + Hart Connectors | 16 | Not Applicable | |||||||||||||
| TB-D5208-GMI-001 | N° 8 / 22mm Modules AI-AO-DI-DO Board with ELCO 56 Pin Output + Hart Connectors | 32 | Not Applicable | |||||||||||||
| TB-D5216-GMI-001 | N° 16 / 22mm Modules AI-AO-DI-DO Board with ELCO 56 Pin Output + Hart Connectors | 32 | Not Applicable | |||||||||||||
| TB-D5008F-GMI-001 | N° 8+2 (Fault) / 12mm Modules AI-AO-DI-DO Board + with ELCO 56 Pin Output + Hart Connectors | 16 | Not Applicable | |||||||||||||
| HIMA HI-MAX BOARDS | ||||||||||||||||
| TB-D5016-HIM-001 | N° 16 / 12mm Modules AI-AO-DI-DO Board 16 Channels Master Board with HiMax & Hart Connector | 32 | Not Applicable | 300 | ||||||||||||
| TB-D5016-HIM-002 | N° 16 / 12mm Modules AI-AO-DI-DO Board 16 Channels Slave Board with HiMax & Hart Connector | 32 | Not Applicable | 300 | ||||||||||||
| TB-D5216-HIM-001 | N° 16 / 22mm Modules AI-AO-DI-DO Board 16 Channels Master Board with HiMax & Hart Connector | 32 | Not Applicable | 460 | ||||||||||||
| TB-D5216-HIM-002 | N° 16 / 22mm Modules AI-AO-DI-DO Board 16 Channels Slave Board with HiMax & Hart Connector | 32 | Not Applicable | 460 | ||||||||||||
| FOXBORO FBM 200 BOARDS | ||||||||||||||||
| TB-D5008-FOX-001 | N° 8 / 12mm Modules AI Board for FBM 214 Board | 16 | Not Applicable | |||||||||||||
| TB-D5008-FOX-002 | N° 8 / 12mm Modules AO Board for FBM 215 Board | 16 | Not Applicable | |||||||||||||
| N° 16 / 12mm Modules DI Board for FBM 217 Board | 32 | Not Applicable | ||||||||||||||
| TRICONEX TMR BOARDS | ||||||||||||||||
| TB-D5016-TRX-001 | N° 16 / 12mm Modules AI Board for TMR 3720 Board | 32 | Not Applicable | |||||||||||||
| TB-D5016-TRX-002 | N° 16 / 12mm Modules DI Board for TMR 3504E Board | 32 | Not Applicable | |||||||||||||
| ABB BOARDS | ||||||||||||||||
| Not Applicable | ||||||||||||||||
| Not Applicable | ||||||||||||||||
| YOKOGAWA CENTUM BOARDS | ||||||||||||||||
| Not Applicable | ||||||||||||||||
| Not Applicable | ||||||||||||||||
| YOKOGAWA PROSAFE BOARDS | ||||||||||||||||
| Not Applicable | ||||||||||||||||
| Not Applicable | ||||||||||||||||
| HONEYWELL TDC 3000 BOARDS | ||||||||||||||||
| TB-D5016-HON-001 | N° 16 / 12mm Modules Board for IOP, HLAI, CC, P/N 51304754-150 Analog Input Type | 32 | Not Applicable | 12 | ||||||||||||
| TB-D5016-HON-002 | N° 16 / 12mm Modules Board for IOP, A/O, CC, P/N 51309152-175, Analog Output Type | 32 | Not Applicable | 12 | ||||||||||||
| Not Applicable | ||||||||||||||||
| Not Applicable | ||||||||||||||||
| S.E.I.D. BOARD | ||||||||||||||||
| TB-D5822-SEID-001 | N° 8 / 12mm Modules Board for 16 Channels with Connector Phoenix 14 Pin | Not Applicable | ||||||||||||||
| BOARD MOUNTING OPTIONS & ACCESSORIES | ||||||||||||||||
| TB-OPT-DIN-001 | Kit for DIN Rail Mounting for termination board D5000 Series; (1 Piece) | Not Applicable | - | |||||||||||||
| N° 1 pieces required for 8 positions Termination Boards; N° 2 pieces required for 16 positions TB | ||||||||||||||||
| TB-OPT-WALL-001 | Kit for Wall Mounting for termination board D5000 Series; M4 Threads ( 20 pieces) | Not Applicable | - | |||||||||||||
| N° 4 pieces required for 8 positions Termination Boards; N° 6 pieces required for 16 positions TB | ||||||||||||||||
| TB-OPT-WALL-002 | Kit for Wall Mounting for termination board D5000 Series; Self Threading (20 Pieces) | Not Applicable | - | |||||||||||||
| N° 4 pieces required for 8 positions Termination Boards; N° 6 pieces required for 16 positions TB | ||||||||||||||||
| Notes | NA = Not Available. Size = Width in mm | |||||||||||||||
| Page # 11 | ||||||||||||||||
| Export Price List 2011 ( Rev. 0 dated December 23rd 2010 ) | ||||||||||||||||
| Code | Description | Ch | Certifications | Size | ||||||||||||
| TEMPERATURE AND DIGITAL I.S. MULTIPLEXER | ||||||||||||||||
| D2000 Series | ||||||||||||||||
| D2010M | 16 Analog-temperature Input channels Intrinsically Safe Multiplexer unit, | 16 | I, A, R, FM | 127 | ||||||||||||
| for installation in hazardous Areas, in congiunction with the D2050 unit, | ||||||||||||||||
| Din Rail Mounting. 4 D2010 can be connected to a D2050 unit | ||||||||||||||||
| D2011M | 16 Analog-temperature Input channels Intrinsically Safe Multiplexer-Expander unit, | 16 | I, A, R, FM | 127 | ||||||||||||
| for installation in hazardous Areas, in congiunction with the D2050 unit, | ||||||||||||||||
| Din Rail Mounting, 3 D2011 can be connected to a D2010 unit. | ||||||||||||||||
| D2030M | 32 Digital Input channels Intrinsically Safe Multiplexer unit, | 32 | I, A, R, FM | 127 | ||||||||||||
| D2050M | Supply Interface unit for redundant comunication with up to 4 D2010-2030 units, | 256 | I, A, R, FM | 127 | ||||||||||||
| for installation in Safe Areas, Din Rail Mounting, | ||||||||||||||||
| RTU Modbus redundant output line RS485 | ||||||||||||||||
| D2052M | 32 Relay Output Module to repeat D2030 input contacts, connection to D2050 | 32 | Not Applicable | 127 | ||||||||||||
| D2053M | 32 Transistor Output Module to repeat D2030 input contacts, connection to D2050 | 32 | Not Applicable | 127 | ||||||||||||
| OPTIONS & ACCESORIES | ||||||||||||||||
| D1090Q | 4 Channels Shunt Module for mA inputs of D2010 & D2011 Units | Not Applicable | 22 | |||||||||||||
| D1094Q | 4 Channels Shunt Module for V inputs of D2010 & D2011 Units | Not Applicable | 22 | |||||||||||||
| OPT2091 | Cold Junction Compensator to be ordered for THCs Inputs Mounted on Terminal Block | Not Applicable | - | |||||||||||||
| 1 compensator per each D2010M - D2011M units | ||||||||||||||||
| OPT2094 | Wall Mounting KIT for GM 2300 Series Enclosures | Not Applicable | - | |||||||||||||
| OPT2095 | Front Door Mounting KIT for GM 2300 Series Enclosures | Not Applicable | - | |||||||||||||
| MOR 016 | Din Rail Stopper | Not Applicable | 5 | |||||||||||||
| MOR 045 | Double Terminal Block to anchor CABF008 Line wires & shield | Not Applicable | 5 | |||||||||||||
| CABF005 | 15 cm flat cable to interconnect D2010M - D2011M units | Not Applicable | - | |||||||||||||
| CABF006 | 30 cm flat cable to interconnect D2010M - D2011M units | Not Applicable | - | |||||||||||||
| CABF007 | 50 cm flat cable to interconnect D2010M - D2011M units | Not Applicable | - | |||||||||||||
| CABF008 | Cable to interconnect D2050M with D2010Mor D2030M units (price per meter), | Not Applicable | - | |||||||||||||
| CABF022 | 15 cm flat cable to interconnect D2050M - D2052M - D2053M units | Not Applicable | - | |||||||||||||
| CABF023 | 30 cm flat cable to interconnect D2050M - D2052M - D2053M units | Not Applicable | - | |||||||||||||
| CABF024 | 50 cm flat cable to interconnect D2050M - D2052M - D2053M units | Not Applicable | - | |||||||||||||
| CABF010 | Sub D 9 Poles Female-Female Nul-Modem, 1800 mm lenght for RS-232 connection | Not Applicable | - | |||||||||||||
| PPC2094 | Optional Kit for System Demo Via RS-485 Modbus & RS-232 Serial Port. | Not Applicable | - | |||||||||||||
| PPC2095 | Optional Kit for System Demo Via RS-232 Serial Port only. | Not Applicable | - | |||||||||||||
| SWC2090 | Software for configuration available on our web site free of charge | Not Applicable | - | |||||||||||||
| ENCLOSURES | ||||||||||||||||
| D2000 Series | ||||||||||||||||
| GM2320-SS-20- NB-M20 | Stainless Steel Enclosure, For installation of N° 1 D2010M Module. 1.880,00 FF Dim.: 400x400x200 mm. With a total of N° 16 M20-DN07 + N° 4 M20-DN1.1 Nichel Plated Brass Cable Glands. Net weight 10,5 Kgs. | |||||||||||||||
| Suitable for N° 1 - D2010M module | ||||||||||||||||
| GM2320-SS-36- NB-M20 | Stainless Steel Enclosure, For installation of N° 1 D2030M Module. 2.120,00 FF Dim.: 400x400x200 mm. With a total of N° 32 M20-DN07 + N° 4 M20-DN1.1 Nichel Plated Brass Cable Glands. Net weight 12,0 Kgs. | |||||||||||||||
| Suitable for N° 1 - D2030M module | ||||||||||||||||
| GM2330-SS-36- NB-M20 | Stainless Steel Enclosure, For installation of N° 2 D2010M or N° 1 D2011M & N° 1 D2011M Modules. | |||||||||||||||
| Dim.: 600x400x200 mm. With a total of N° 32 M20-DN07 + N° 4 M20-DN1.1 Nichel Plated Brass Cable Glands. Net weight 17,0 Kgs. | ||||||||||||||||
| Suitable for N° 1 - D2030M module or N° 2 - D2010M modules or N° 1 - D2010M + N° 1 D2011M modules | ||||||||||||||||
| GM2330-SS-52- | Stainless Steel Enclosure, For installation of N° 1 D2010M & N° 1 D2030M Modules or N° 1 D2010M & N° 2 D2011M Mod. | |||||||||||||||
| NB-M20 | Dim.: 600x400x200 mm. With a total of N° 48 M20-DN07 + N° 4 M20-DN1.1 Nichel Plated Brass Cable Glands. Net weight 20,0 Kgs. | |||||||||||||||
| Suitable for N° 3 - D2010M module or N° 1 - D2010M + N° 2 D2011M modules | ||||||||||||||||
| GM2330-SS-68- NB-M20 | Stainless Steel Enclosure, For installation of N° 4 D2010M / D2011M or N° 2 D2030M Modules. 2.710,00 FF Dim.: 600x400x200 mm. With a total of N° 64 M20-DN07 + N° 4 M20-DN1.1 Nichel Plated Brass Cable Glands. Net weight 20,0 Kgs. | |||||||||||||||
| Suitable for N° 2 - D2030M module or N° 4 - D2010M modules or N° 1 - D2010M + N° 3 D2011M modules or N° 2 - D2010M + N° 2 D2011 M mod. | ||||||||||||||||
| Certifications | I= IEC; A= ATEX; R= GOST; UL= Underwriter Laboratories; FM= Factory Mutual; T= TUV; E= Exida; M= Marine; Up to date info: www.gmintsrl.com | |||||||||||||||